High voltage wire

High-voltage cable is a type of power cable, which refers to a power cable used to transmit between 10kv-35kv (1kv=1000v), and is mostly used in the main road of power transmission. The product implementation standards for high-voltage cables are gb/t 12706.2-2008 and gb/t 12706.3-2008

Types of high-voltage cables

The main types of high-voltage cables are yjv cable, vv cable, yjlv cable, and vlv cable.

yjv cable full name XLPE insulated PVC sheathed power cable (copper core)

The full name of vv cable is PVC insulated and sheathed power cable (copper core)

yjlv cable full name XLPE insulated PVC sheathed aluminum core power cable

VLV cable full name PVC insulated PVC sheathed aluminum core power cable

Due to the excellent electrical conductivity of copper conductors, more and more projects use copper core power cables as the main road of the power supply system, while aluminum core power cables are less used, especially in the higher-voltage power system, choose copper core The more cables there are.

The structure of high-voltage cables

The components of a high-voltage cable from the inside to the outside include: conductor, insulation, inner sheath, filler (armor), and outer insulation. Of course, armored high-voltage cables are mainly used for underground burying, which can resist high-strength compression on the ground and prevent damage from other external forces.

Common specifications and uses

na-yjv, nb-yjv, XLPE insulated PVC sheathed a(b) fire-resistant power cables can be laid in indoors, tunnels and pipelines that require fire resistance.

na-yjv22, nb-yjv22, XLPE insulated steel tape armored PVC sheathed a(b) fire-resistant power cable is suitable for laying in the ground when fire resistance is required, not suitable for laying in pipelines.

na-vv, nb-vv, PVC insulated PVC sheathed a(b) fire-resistant power cable can be laid in indoors, tunnels and pipelines that require fire resistance.

na-vv22, nb-vv22, PVC insulated steel tape armored PVC sheathed type a (b) fire-resistant power cables are suitable for laying in the ground when fire resistance is required, but not suitable for laying in pipelines.

wdna-yjy23, wdnb-yjy23, cross-linked polyethylene insulated steel tape armored polyolefin sheathed a(b) halogen-free low-smoke fire-resistant power cable is suitable for laying in the ground when halogen-free, low-smoke and fire resistance are required, not suitable Laying in the pipeline.

za-yjv, za-yjlv, zb-yjv, zb-yjlv, zc-yjv, zc-yjlv, cross-linked polyethylene insulated PVC sheathed a (b, c) flame-retardant power cable can be laid in the opposite resistance Fired indoors, tunnels and pipelines with requirements.

za-yjv22, za-yjlv22, zb-yjv22, zb-yjlv22, zc-yjv22, zc-yjlv22, cross-linked polyethylene insulated steel tape armored PVC sheathed a (b, c) flame retardant power cable is suitable It is not suitable for laying in the pipeline when laying in the ground when flame retardant is required.

za-vv, za-vlv, zb-vv, zb-vlv, zc-vv, zc-vlv, PVC insulated PVC sheathed a (b, c) flame-retardant power cable can be laid on the flame-retardant Indoors, tunnels and pipelines where required.

za-vv22, za-vlv22, zb-vv22, zb-vlv22, zc-vv22, zc-vlv22, PVC insulated steel tape armored PVC sheathed a (b, c) flame retardant power cable suitable for Laying in the ground when flame retardant is required is not suitable for laying in pipelines.

wdza-yjy, wdza-yjly, wdzb-yjy, wdzb-yjly, wdzc-yjy, wdzc-yjly, cross-linked polyethylene insulated polyolefin sheathed a (b, c) flame-retardant power cables can be laid in flame-retardant And in indoors, tunnels and pipelines where halogen-free and low-smoke are required.

wdza-yjy23, wdza-yjly23, wdzb-yjy23, wdzb-yjly23, wdzc-yjy23, wdzc-yjly23,

Cross-linked polyethylene insulated steel tape armored polyolefin sheathed a (b, c) flame-retardant power cables are suitable for laying in the ground when flame-retardant, halogen-free and low-smoke are required, and not suitable for laying in pipelines.

vv, vlv, copper (aluminum) core PVC insulated and PVC sheathed power cables are laid indoors, tunnels and pipes or outdoor brackets, and are not subject to pressure and mechanical external forces

vy, vly, copper (aluminum) core PVC insulated and PE sheathed power cable

vv22, vlv22, copper (aluminum) core PVC insulated steel tape armored PVC sheathed power cables are laid indoors, tunnels, cable trenches and directly buried soil, the cables can withstand pressure and other external forces

vv23, vlv23, copper (aluminum) core PVC insulated steel tape armored PE sheathed power cable

High voltage cable use characteristics

This product is suitable for AC rated voltage 35kv and below for power transmission and distribution. The maximum long-term working temperature of the cable conductor is 90 degrees, and the maximum temperature of the cable conductor does not exceed 250 degrees when short-circuited (the longest time does not exceed 5s).

UHV cable

1kv and below are low voltage cables; 1kv~10kv are medium voltage cables; 10kv~35kv are high voltage cables; 35~220kv are UHV cables;

UHV cable is a kind of power cable that has emerged with the continuous development of cable technology. UHV cable is generally used as a central hub in large-scale power transmission systems. It is a high-voltage cable with high technical content and is mainly used for long-distance power transmission.

Causes of high-voltage cable failure

The cable is the bridge between the power supply equipment and the electrical equipment, and plays the role of transmitting electric energy. It is widely used, so failures often occur. The following is a brief analysis of the causes of common problems of high-voltage cables. According to the causes of failures, they are roughly divided into the following categories: manufacturer manufacturing reasons, construction quality reasons, design units design reasons, external force damage Four categories.


Product detail pictures:

Wholesale Dealers of D/D-Sub Cable Assembly - High Voltage Cable – Sunshow detail pictures

Wholesale Dealers of D/D-Sub Cable Assembly - High Voltage Cable – Sunshow detail pictures


Related Product Guide:

Our personnel are always in the spirit of "continuous improvement and excellence", and together with the top-quality good quality solutions, favorable selling price and superior after-sales providers, we try to acquire each customer's rely on for Wholesale Dealers of D/D-Sub Cable Assembly - High Voltage Cable – Sunshow, The product will supply to all over the world, such as: Tunisia, Manchester, Kenya, Based on our guiding principle of quality is the key to development, we continually strive to exceed our customers' expectations. As such, we sincerely invite all interested companies to contact us for future cooperation, We welcome old and new customers to hold hands together for exploring and developing; For more information, please feel free to contact us. Thanks. Advanced equipment, strict quality control, customer-orientation service, initiative summary and improvement of defects and extensive industry experience enable us to guarantee more customer satisfaction and reputation which, in return, brings us more orders and benefits. If you are interested in any of our products, please feel free to contact us. Inquiry or visit to our company are warmly welcome. We sincerely hope to start a win-win and friendly partnership with you. You can see more details in our website.
  • It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
    5 Stars By Eileen from France - 2018.06.05 13:10
    Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Jerry from Armenia - 2018.12.28 15:18